Transformer - Wikipedia, the free encyclopedia. A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Electromagnetic induction produces an electromotive force within a conductor which is exposed to time varying magnetic fields. Transformers are used to increase or decrease the alternating voltages in electric power applications. Selecting Current Transformers Part 1 PDF: TRANSFORMER DIFFERENTIAL PROTECTION SCHEME WITH INTERNAL FAULTS PDF. Transformers: Basics, Maintenance, and Diagnostics book 8.8 out of 10 based on 26 ratings.A varying current in the transformer's primary winding creates a varying magnetic flux in the transformer core and a varying field impinging on the transformer's secondary winding. This varying magnetic field at the secondary winding induces a varying electromotive force (EMF) or voltage in the secondary winding due to electromagnetic induction. Making use of Faraday's Law (discovered in 1. AC voltages from one voltage level to another within power networks. Since the invention of the first constant potential transformer in 1. Three Phase Transformer Basics. In this case four single phase transformers are used. A balanced electrical system analysis is done in per phase basis. Electrical Machines IProf. Krishna Vasudevan, Prof. Sasidhara Rao 2 Basic Principles As mentioned. 101 BASICS SERIES FUNDAMENTALS OF ELECTRICAL DISTRIBUTION Cutler-Hammer. 1 FUNDAMENTALS OF ELECTRICAL DISTRIBUTION Welcome to Module 3, Fundamentals of Electrical. Basic Electrical; Circuit Theories. Definition and Working Principle of Transformer. Single Three Phase Transformer vs bank of three Single Phase Transformers. Electrical Tutorial about Current Transformer Basics and Current Transformer Theory on how the current transformer works with just one secondary winding. What is a Transformer? An Electrical Transformer Tutorial Afroman covers the basics of how transformers work, where to shop for step down mains transformers, and how to wire one up to mains voltages without. TRANSFORMERS Transformers are commonly used in applications which require the conversion of AC voltage from one. There is no electrical connection between the coils, they are connected to each other through magnetic. Transformers insulated with such a liquid are designated as askarel-insulated transformers. 450.23 of the National Electrical Code. TRANSFORMERS 5.5 FIGURE 5.6Longitudinal section of air-blast transformer, showing. Transformers range in size from RF transformers less than a cubic centimeter in volume to units interconnecting the power grid weighing hundreds of tons. Basic principles. Ideal transformer. Ideal transformer equations (eq.)By Faraday's law of induction: VS=. An ideal transformer is a theoretical, linear transformer that is lossless and perfectly coupled; that is, there are no energy losses and flux is completely confined within the magnetic core. Perfect coupling implies infinitely high core magnetic permeability and winding inductances and zero net magnetomotive force. This varying magnetic field at the secondary induces a varying electromotive force (EMF) or voltage in the secondary winding. The primary and secondary windings are wrapped around a core of infinitely high magnetic permeability. With a voltage source connected to the primary winding and load impedance connected to the secondary winding, the transformer currents flow in the indicated directions. Positively increasing instantaneous current entering the primary winding's dot end induces positive polarity voltage at the secondary winding's dot end. In practice, some flux traverses paths that take it outside the windings. It is not directly a power loss, but results in inferior voltage regulation, causing the secondary voltage not to be directly proportional to the primary voltage, particularly under heavy load. The basics of how transformers work. An Electrical Transformer Tutorial. It can be shown that if the percent impedance. VA unit in parallel with 1,0. VA unit, the larger unit would carry twice the current). However, the impedance tolerances of commercial transformers are significant. Also, the Z impedance and X/R ratio of different capacity transformers tends to vary, corresponding 1,0. VA and 5. 00 k. VA units' values being, to illustrate, respectively, Z . Magnetizing current is in phase with the flux, the relationship between the two being non- linear due to saturation effects. However, all impedances of the equivalent circuit shown are by definition linear and such non- linearity effects are not typically reflected in transformer equivalent circuits. With open- circuited secondary winding, magnetizing branch current I0 equals transformer no- load current. This introduces error but allows combination of primary and referred secondary resistances and reactances by simple summation as two series impedances. Transformer equivalent circuit impedance and transformer ratio parameters can be derived from the following tests: open- circuit test. However, properties such as core loss and conductor skin effect also increase with frequency. Aircraft and military equipment employ 4. Hz power supplies which reduce core and winding weight. Hz and 2. 5 Hz) than normal utility frequencies (5. Consequently, the transformers used to step- down the high overhead line voltages (e. V) were much larger and heavier for the same power rating than those required for the higher frequencies. At a lower frequency, the magnetizing current will increase. Operation of a transformer at other than its design frequency may require assessment of voltages, losses, and cooling to establish if safe operation is practical. For example, transformers may need to be equipped with 'volts per hertz' over- excitation relays to protect the transformer from overvoltage at higher than rated frequency. One example is in traction transformers used for electric multiple unit and high- speed train service operating across regions with different electrical standards. The converter equipment and traction transformers have to accommodate different input frequencies and voltage (ranging from as high as 5. Hz down to 1. 6. 7 Hz and rated up to 2. V) while being suitable for multiple AC asynchronous motor and DC converters and motors with varying harmonics mitigation filtering requirements. Large power transformers are vulnerable to insulation failure due to transient voltages with high- frequency components, such as caused in switching or by lightning. The development of switching power semiconductor devices and complex integrated circuits made switch- mode power supplies viable, to generate a high frequency from a much lower one (or DC), change the voltage level with a small transformer, and, if necessary, rectify the changed voltage. Energy losses. Real transformer energy losses are dominated by winding resistance joule and core losses. Transformers' efficiency tends to improve with increasing transformer capacity. The efficiency of typical distribution transformers is between about 9. Hysteresis and eddy current losses are constant at all load levels and dominate overwhelmingly without load, while variable winding joule losses dominating increasingly as load increases. The no- load loss can be significant, so that even an idle transformer constitutes a drain on the electrical supply. Designing energy efficient transformers for lower loss requires a larger core, good- quality silicon steel, or even amorphous steel for the core and thicker wire, increasing initial cost. The choice of construction represents a trade- off between initial cost and operating cost. As frequency increases, skin effect and proximity effect causes the winding's resistance and, hence, losses to increase. Core losses. Hysteresis losses. Each time the magnetic field is reversed, a small amount of energy is lost due to hysteresis within the core. According to Steinmetz's formula, the heat energy due to hysteresis is given by. Wh. Eddy currents therefore circulate within the core in a plane normal to the flux, and are responsible for resistive heating of the core material. The eddy current loss is a complex function of the square of supply frequency and inverse square of the material thickness. However, any leakage flux that intercepts nearby conductive materials such as the transformer's support structure will give rise to eddy currents and be converted to heat. This energy incites vibration transmission in interconnected metalwork, thus amplifying audible transformer hum. When windings surround the core, the transformer is core form; when windings are surrounded by the core, the transformer is shell form. Shell form design may be more prevalent than core form design for distribution transformer applications due to the relative ease in stacking the core around winding coils. At higher voltage and power ratings, shell form transformers tend to be more prevalent. Each lamination is insulated from its neighbors by a thin non- conducting layer of insulation. Thinner laminations reduce losses. The cut- core or C- core type is made by winding a steel strip around a rectangular form and then bonding the layers together. It is then cut in two, forming two C shapes, and the core assembled by binding the two C halves together with a steel strap. When power is then reapplied, the residual field will cause a high inrush current until the effect of the remaining magnetism is reduced, usually after a few cycles of the applied AC waveform. On transformers connected to long, overhead power transmission lines, induced currents due to geomagnetic disturbances during solar storms can cause saturation of the core and operation of transformer protection devices. The higher initial cost of the core material is offset over the life of the transformer by its lower losses at light load. These materials combine high magnetic permeability with high bulk electrical resistivity. For frequencies extending beyond the VHF band, cores made from non- conductive magnetic ceramic materials called ferrites are common. The closed ring shape eliminates air gaps inherent in the construction of an E- I core. The primary and secondary coils are often wound concentrically to cover the entire surface of the core. This minimizes the length of wire needed and provides screening to minimize the core's magnetic field from generating electromagnetic interference. Toroidal transformers are more efficient than the cheaper laminated E- I types for a similar power level. Other advantages compared to E- I types, include smaller size (about half), lower weight (about half), less mechanical hum (making them superior in audio amplifiers), lower exterior magnetic field (about one tenth), low off- load losses (making them more efficient in standby circuits), single- bolt mounting, and greater choice of shapes. The main disadvantages are higher cost and limited power capacity (see Classification parameters below). Because of the lack of a residual gap in the magnetic path, toroidal transformers also tend to exhibit higher inrush current, compared to laminated E- I types. Ferrite toroidal cores are used at higher frequencies, typically between a few tens of kilohertz to hundreds of megahertz, to reduce losses, physical size, and weight of inductive components. A drawback of toroidal transformer construction is the higher labor cost of winding. This is because it is necessary to pass the entire length of a coil winding through the core aperture each time a single turn is added to the coil. As a consequence, toroidal transformers rated more than a few k.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
January 2017
Categories |